Page view 37
Procedure ->Test Program
No. Process
0 Initialization
1Inlet Valve
2
Washing Pump
and Dispenser
3 Heating Element
4Drain Pump
5Pause
6Inlet Valve
7 Washing Pump
8 Washing Pump
9 Washing Pump
10
Inlet valve and
Regeneration
Valve
11 Drain Pump
12 Finish Buzz one, then pause.F*
08
07
06
Drain for 30s.
Pause for 10s.
Open inlet valve and feeds with 3.2L water.
Procedure of Test Program (for models controlling water filling by flowmeter)
Display on
the screen
0b
0A
09/water
temperature
Description
Power on, stand by
Open inlet valve and feeds with 3.6L water. the divter will move to
position rotating both upper and lower spray arm.
8:88
01 drain for 30s.
Dispenser will act once and washing pump will run for 60s in this step.
Run washing pump and heating element until the water temperature
reaches 57℃. Then the machine will pause. Two spray arm would rotate
alternatively.
Press Program button to jump into the next step.
Open regenaeration valve and feed with 0.3L water
05
04
03
02
Run washing pumo for 2 mins, and the diverter will be positioned in place
rotating upper spray arm only.
Run washing pumo for 2 mins, and the diverter will be positioned in place
rotating lower spray arm only.
Run washing pumo for 1 min, and the diverter will be positioned in place
rotating both upper and lower spray arm.