INSTRUCTION MANUALBHG900.6SS - 90 cm 5 Burner Gas Hob
ADJUSTMENTSAlways disconnect the appliance from theelectricity main before making any adjustments.All seals must be replaced by the technician at
10) REPLACING THE INJECTORSThe burners can be adapted to different types ofgas by mounting injectors suited to the type of gas in question. To d
11SERVICINGAlways disconnect the appliance from theelectricity and gas mains before proceedingwith any servicing operation.11)REPLACING HOB PA
12SERVICINGCABLE TYPES AND SECTIONSHHOB Gas Gas HobH05 RR - F Section 3 x 0.75 mm2TYPE OFHOBTYPE OF SINGLE - PHASECABLE POWER SUPPLYATTENTION!!!If the
13TECHNICAL DATA ON THE DATA LABEL5 BURNERS (70) CAT. = II2H3+G30-BUTANE = 28-30 mbarG31-PROPANE = 37 mbarG20-NATURAL = 20 mbarTot. Nom. Gas Rate
14TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION
15Before leaving the factory, this appliance will have been tested and regulated by expert and specialised personnel in order to guarantee the best pe
16
United Kingdom Baumatic Ltd., Baumatic Buildings, 6 Bennet Road, Reading, Berkshire RG2 0QX United Kingdom Sales Telephone (0118) 933 6900 Sales
The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors; the designs in the figur
www.baumatic.com
DESCRIPTION OF THE GAS HOBS2MOD: MOD: MOD: BHG900.6SSMOD: of 3100 Wof 2800 W of 1750 W of 1000 W1 Ultra rapid burner2 Rapid burner3 Semirapid
1) BURNERSA diagram is printed above each knob on the front panel. This diagram indicates to whichburner the knob in question corresp
USEWARNINGS AND ADVICE FOR THE USER:Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must ther
CLEANINGIMPORTANT:Always disconnect the appliance from the gasand electricity mains before carrying out anycleaning operation.2)GAS HOBPeriodica
INSTALLATIONTECHNICAL INFORMATION FOR THEINSTALLERInstallation, adjustments of controls andmaintenance must only be carried out by aqualifie
IMPO RTANT INSTA L LATIONSPEC IFICATI O NSThe rear wall and the surfaces surrounding and adjacent to the appliance must be able to with
8) ELECTRICAL CONNECTIONThe electrical connections of the appliancemust be carried out in compliance with theprovisions and standards in forc